Felder | RL 300 Clean Air Dust Extractor
Healthier Workshops with High-Performance Dust Extraction
The Felder RL 300 Clean Air Dust Extractor delivers professional-grade dust and chip extraction for wood, panel, and plastic materials. With a Ø 11 13/16" (300 mm) extraction connector, 3530 CFM max airflow, and a 2 x 55.5-gallon chip collection capacity, it ensures a dust-free workspace with a residual dust concentration of less than 0.1 mg/m³, meeting H3 standards.
Key Features
Highlights
- Cartridge Filter System: 50 m² filter surface area with continuous JET cleaning via compressed air for long-lasting extraction performance.
- Chip Collection Bins: Optimized 2 x 55.5-gallon bins with quick-change clamping system for efficient dust bag replacement.
- Negative Pressure Design: Ventilator positioned behind filters prevents dust escape, ensuring a cleaner workshop.
Details
- Extraction Connector: Ø 11 13/16" (300 mm) for high-volume dust extraction.
- Automatic Filter Cleaning: Continuous compressed air blasts maintain filter efficiency.
- Optional Rotary Valve: Replaces chip collection bins for continuous operation, with Ø 160 mm suction pipe compatibility.
- Fire Safety: Standard water fire extinguisher, optional powder fire extinguisher.
- Automatic Start Options: Supports 1–8 machines with optional electric gates, including freely programmable configurations.
- Anti-Static Filter: Optional feature for enhanced safety in dust-prone environments.
- Sound Absorber: Optional accessory reduces acoustic pressure to 75 dB for quieter operation.
- Extraction Port Flexibility: Optional left-hand side extraction port for customized workshop setups.
Technical Specifications
| Category | Details |
|---|---|
| Electrics |
|
| General |
|
| Automatic Start |
|
| Accessories |
|
Specifications
Felder RL 300 Clean Air Dust Extractor FAQs
What type of extractor is the RL 300?
A clean-air dust extractor with the fan on the filtered-air side.
What is the maximum airflow?
6,000 m³/h in Felder's model overview.
What is the nominal airflow?
5,090 m³/h at 20 m/s in the model overview.
Why distinguish nominal and maximum airflow?
Use the operating airflow and pressure requirements of the connected equipment when sizing a system.
What inlet diameter is specified?
300 mm.
What filter surface is listed?
50 m².
What residual dust level does Felder state?
Below 0.1 mg/m³ in the extracted, filtered air.
Does that rating describe the whole workshop?
No. Actual workplace exposure depends on capture, installation and operating conditions.
How is waste collected?
Collection capacity is listed as two approximately 55.5-US-gallon bins.
How are collection bags changed?
Bins beneath the extractor use a clamping system.
Is automatic filter cleaning standard?
JET cleaning uses automatic compressed-air pulses.
Is automatic machine starting available?
Optional start systems monitor one to eight machines; gate-control versions are also offered.
Does automatic starting guarantee simultaneous capacity?
No. Check total airflow and duct losses for the machines that will operate together.
What acoustic pressure is listed?
75 dB in the technical table.
What must the installation quotation confirm?
Electrical supply, duct layout, cleaning-air requirements and the supplied filter and collection configuration.